Installation & Operation Manual CAMCO eSwitch Programmable Limit Switch Part No: 87C91663000000 WARNING This is a controlled document
10 www.destaco.com Program Window Features Get Values From eSwitch Pressing this button will copy the values stored in the eSwitch to left tab of the
www.destaco.com 11 Example eSwitch Set Up 1. Press Get Values From eSwitch (retrieves any existing program) or Get Values From File (for new program
12 www.destaco.com 3. Confirm the timing shaft (CAMCO Unit Input Shaft) is turned to the home position. Put it in the home position if it is not. 4.
www.destaco.com 13 7. Select the Output channel to be edited 8. Change the Sequence or Sequences. Select values for degrees of input rotation for w
14 www.destaco.com 9. Press Update Values To Table to update the Value table with the new sequence values. 10. Repeat steps 7 through 9 for each ch
www.destaco.com 15 12. Press Send Values To File to save the values to a file for backup or for transfer to another eSwitch 13. When programming is
CAMCO & FERGUSON Products 1444 South Wolf Road Wheeling, IL 60090 USA ph: 847-459-5200 toll-free: 800-645-5200 fax: 847-459-3064 camco@destaco
www.destaco.com 3 CAMCO eSwitch Programmable Switch Table of Contents Introduction...
4 www.destaco.com Introduction This service manual describes the setup and operation of the CAMCO eSwitch. The eSwitch is a programmable multi-channe
www.destaco.com 5 eSwitch Mounting Parts Part Numbers Description DE-STA-CO Part No. Supplier Part No eSwitch 87C91663000000 - 12-Pin Cable (2-me
6 www.destaco.com Installing Software In order to use the eSwitch you will need to install the application program “eSwitch” and a USB driver. eSwit
www.destaco.com 7 eSwitch Setup Mount the Actuator If eSwitch is not already mounted 1. Drill and tap an M6 thread into the center of the timing shaf
8 www.destaco.com 3. eSwitch Data Connector Pin Numbers NOTE: All outputs must be connected to COMMON (“daisy-chained”) to complete the circuit. Da
www.destaco.com 9 3. Under “Ports,” the VCP should be shown as COM6. If it is not 6, note the number shown. Note: If the Com port is not 6, then you